Initialize the volume, vary it online, define the VVDS, and then add it
to the SMS configuration.  If it has not been added to an SMS storage
group, SMS will not try to allocate a data set on it.



-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of willie bunter
Sent: Monday, September 18, 2006 7:14 AM
To: [email protected]
Subject: CATALOG ERROR - Defining VVDS


Good Day,
   
  I encountered the following error while I was attempting to define the
VVDS on a 3390-9 disk which is SMS managed:
   
  IDC3014I CATALOG ERROR

IDC3009I ** VSAM CATALOG RETURN CODE IS 50 - REASON CODE IS IGG0CLE3-8 
IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12                     

  I checked the error code and it points out to the fact that "a VVDS
already exists on the volume"
   
  I am not sure how that can happen because I initialized the volume
(ICKDSF) and put it online and attempted to define the VVDS.  Can it be
because as soon as I put the volume online a VSAM file may have been
allocated on that volume?  If so, how can I avoid this problem in the
future.  
   
  Here is my init job
   
  INIT -                
     UNITADDRESS(BC50)
     VOLID(PAS904) -  
     VTOC(0,1,149) -  
     VERIFY(SPAC50) - 
     INDEX(10,0,45) - 
     STORAGEGROUP

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to