>Probably good time to review JES parms too!
>
>AUTH=ALL|SYS|IO|CONS|INFO
>Specifies the MVS operator command groups that are to be  executed. The
>groups include:


Yes, I tried to suggest turning off commands from JCL, but management was 
afraid there may be legitimate commands in production jobs. Whatever. They 
chose to whack the QUIESCE command via RACF. 

But getting back to the RESTART, is there a possibility of affecting the 
wrong lpar? Let's say I have two CPC's each with two lpars - one production 
and one test (this is how Lands' End is setup!). I QUIESCE one of the test 
systems. How do I know that the PSW RESTART will restart the right lpar?

According to IBM, the PSW Restart "Performs a restart operation on the 
first available central processor(s) of the selected CPC images (except for 
a coupling facility image). A restart interruption will store the current 
program status word (PSW) at real address 8 and fetch a new PSW from real 
address 0 in central storage."

So my question is how do you direct the restart to the desired lpar? 