Missing comma in IEASYS00 was the problem. Thank you very much!

Francois Pare

-----Message d'origine-----
De : IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] De la part de Mark 
Zelden
Envoyé : 27 novembre 2006 14:51
À : [email protected]
Objet : Re: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB

On Mon, 27 Nov 2006 14:42:54 -0500, François Paré
<[EMAIL PROTECTED]> wrote:

>I'm not able to do a complete first IPL of a new cloned system. It stopped
with the following messages:
>
>IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB
>
>IEA510A LNKLST PROCESSING IS INOPERATIVE, PRESS ENTER TO CONTINUE WITH THE
DEFAULT LNKLST, OR RE-IPL THE SYSTEM
>
>The message seems very clear about the error but LNKLST00 is defined in
member SYS1.PARMLIB(PROG00) as in my production system so any idea?
>

Yes. You are most likely missing a comma somewhere in IEASYSxx prior
to PROG=.  

--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group - GITO
mailto:[EMAIL PROTECTED]
z/OS and OS390 expert at http://searchDataCenter.com/ateExperts/
Systems Programming expert at http://expertanswercenter.techtarget.com/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------