On 12/5/2006 9:33 AM, pzanni wrote:
I would cleanup a Catalog. For this I pass a DIAGNOSE :

  DIAGNOSE VVDS       IDS(SYS1.VVDS.VTST102)   -
       COMPAREDS(CATALOG.IU.VTST001)
IDC2917I NO RACF PROFILE ON STGADMIN.IDC.DIAGNOSE.VVDS
IDC11367I THE FOLLOWING VVDS REFERENCED CATALOGS WERE NOT ENCOUNTERED:
  CATALOG.IU.VGPA144

Can anybody help me ?


From the IDC2917I message I will guess that your security administrator needs to define the FACILITY profile STGADMIN.IDC.DIAGNOSE.VVDS and give you authority to it.

        Walt

ps: When you post to ibm-main via Google groups your message gets to only a limited set of list members, as many members only see messages posted to ibm-main via email. Perhaps you will get additional answers when those members see this reply.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to