Howard, Ah, misread the original message string. The one that applies is: NOTE=010B,H/W AND S/W CONFIGURATION DEFINITIONS WILL BE OUT OF SYNC An ACTIVATE TEST request was entered to test for a software-only configuration change. The target IODF data set does not contain a configuration definition that matches the current hardware definition. If the software-only configuration change was activated, the hardware and software configurations would no longer be synchronized.
System Action: The system continues processing. So, same synopsis, but looks like the HCD options you used might be to "TEST" the configuration and not activate it? Regards, Alan ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html