Howard,

Ah, misread the original message string.
The one that applies is:
NOTE=010B,H/W AND S/W CONFIGURATION DEFINITIONS WILL BE OUT OF SYNC 
An ACTIVATE TEST request was entered to test for a software-only
configuration change. The target IODF data set does not contain a
configuration definition that matches the current hardware definition. If
the software-only configuration change was activated, the hardware and
software configurations would no longer be synchronized. 

System Action: The system continues processing. 


So, same synopsis, but looks like the HCD options you used might be to
"TEST" the configuration and not activate it?

Regards,
Alan

----------------------------------------------------------------------