Hi Paul,
I'm not really shure, but there are two things that I would check in this case:
1. default region size for STC in the JESPARMS (parameter STCCLASS)
2. MAXASSIZE parameter in BPXPRMxx parmlib member 

Greetings,
Volkmar

-----Ursprüngliche Nachricht-----
Von: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] Im Auftrag von 
Beesley, Paul
Gesendet: Dienstag, 12. Dezember 2006 13:26
An: [email protected]
Betreff: S80A loading CEEMENU3

We have recently upgraded from z/OS 1.4 to 1.7.
When attempting to rebuild the Book Server catalog, I get these symptoms from 
the USS[1] task, so the catalog never gets fully rebuilt

IEW4000I FETCH FOR MODULE CEEMENU3 FROM DDNAME -LNKLST- FAILED BECAUSE
INSUFFICIENT STORAGE WAS AVAILABLE.                                   
CSV031I LIBRARY ACCESS FAILED FOR MODULE CEEMENU3, RETURN CODE 24,    
REASON CODE 26080021, DDNAME *LNKLST*                                 
----
IEF450I WEBSRV STEP1 - ABEND=S80A U0000 REASON=00000010 727    
        TIME=11.54.38                                          

IEFUSI hasn't changed and bypasses all checking when the sub system is OMVS.

How do I increase the region available to a spawned task ? 

[1] yes I know I shouldn't call it USS :)



Paul Beesley
UKOSG - Infrastructure Specialist Senior EDS Victoria House Bournemouth
BH1 2NF
Phone: 01202 502334
Mobile: 07790 495140
Please consider your environmental responsibility before printing this e-mail 
or any other document. 




----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to