That's my point. I get an 0c1 with the PSW pointing to a valid
instruction.
SYSTEM COMPLETION CODE=0C1 REASON CODE=00000001
TIME=19.25.42 SEQ=09077 CPU=0000 ASID=0088
PSW AT TIME OF ERROR 078D2000 800791C6 ILC 6 INTC 01
ACTIVE LOAD MODULE ADDRESS=00078FC0 OFFSET=00000206
NAME=DEBCIDID
DATA AT PSW 000791C0 - C1F05010 41204110 00525E10
GR 0: 00000000 1: 00000000
2: 19C2C2A0 3: 19C28AF0
4: 19C28148 5: 8005941C
6: 19CFF888 7: 19C1DE70
8: 80059456 9: 19C1DE60
A: 19CFFBE0 B: 19C1DD88
C: 80078FD0 D: 19C28100
E: 800791BC F: 0000000C
END OF SYMPTOM DUMP
Sysview disassemble around offset 206:
000001FE BNZ 496(,R12) 4770 C1F0
00000202 ST R1,288(,R4) 5010 4120
00000206 LA R1,82 4110 0052
0000020A AL R1,296(,R4) 5E10 4128
0000020E AL R1,992(,R12) 5E10 C3E0
Dave Gibney [EMAIL PROTECTED]
System Programmer (509) 335-7359
Information Technology
Washington State University
Pullman, WA 99164-1222
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
> Behalf Of Chuck Arney
> Sent: Thursday, December 14, 2006 1:09 PM
> To: [email protected]
> Subject: Re: S0C1 with ILC 6
>
> I think you are still confused. :>) An LA instruction can not
program
> check.
>
> Chuck Arney
> illustro Systems International, LLC
> http://www.illustro.com
> Access 3270 data from anywhere with z/XML-Host
> Access 3270 apps from the web with z/Web-Host
> Access CMS minidisks from z/OS or z/VSE with CMSACCess
> Voice: 972-296-6166
> Fax: 214-451-6394
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html