On Thu, 14 Dec 2006 13:15:29 -0800, Gibney, Dave <[EMAIL PROTECTED]> wrote:
> That's my point. I get an 0c1 with the PSW pointing to a valid >instruction. >SYSTEM COMPLETION CODE=0C1 REASON CODE=00000001 > TIME=19.25.42 SEQ=09077 CPU=0000 ASID=0088 > PSW AT TIME OF ERROR 078D2000 800791C6 ILC 6 INTC 01 > ACTIVE LOAD MODULE ADDRESS=00078FC0 OFFSET=00000206 > NAME=DEBCIDID > DATA AT PSW 000791C0 - C1F05010 41204110 00525E10 > Your failing instruction is C1F0 5010 4120. The PSW points to the next instruction that would have been executed. -- Tom Marchant ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html