On Thu, 14 Dec 2006 13:15:29 -0800, Gibney, Dave <[EMAIL PROTECTED]> wrote:

>   That's my point. I get an 0c1 with the PSW pointing to a valid
>instruction.
>SYSTEM COMPLETION CODE=0C1  REASON CODE=00000001
> TIME=19.25.42  SEQ=09077  CPU=0000  ASID=0088
> PSW AT TIME OF ERROR  078D2000   800791C6  ILC 6  INTC 01
>   ACTIVE LOAD MODULE           ADDRESS=00078FC0  OFFSET=00000206
>   NAME=DEBCIDID
>   DATA AT PSW  000791C0 - C1F05010  41204110  00525E10
>  

Your failing instruction is C1F0 5010 4120.  The PSW points to
the next instruction that would have been executed.

-- 
Tom Marchant

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html