*70 IXC102A XCF IS WAITING FOR SYSTEM LS03 DEACTIVATION. REPLY DOWN 
 WHEN MVS ON LS03 HAS BEEN SYSTEM RESET    

According to the message 'DOWN' is AFTER system reset.

>From the timings it is possible that the system reset was started prior
to the IXC102A message.

Thanks for the info, I just needed to know if this 'could' happen or if
it was something I needed to follow up with IBM.


-----Original Message-----
Randy Gross

In my previous life, I had three large (parallel) sysplexes (12, 15, and
21 lpars).  

Occasionally, we would see this situation when the sys reset was done
too early (should be after the reply "down", IIRC); and yes, it would
affect multiple lpars...

Randy

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html