*70 IXC102A XCF IS WAITING FOR SYSTEM LS03 DEACTIVATION. REPLY DOWN WHEN MVS ON LS03 HAS BEEN SYSTEM RESET
According to the message 'DOWN' is AFTER system reset. >From the timings it is possible that the system reset was started prior to the IXC102A message. Thanks for the info, I just needed to know if this 'could' happen or if it was something I needed to follow up with IBM. -----Original Message----- Randy Gross In my previous life, I had three large (parallel) sysplexes (12, 15, and 21 lpars). Occasionally, we would see this situation when the sys reset was done too early (should be after the reply "down", IIRC); and yes, it would affect multiple lpars... Randy ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html