I'm not sure if this has been fixed yet, but you also need to explicitly exclude Type 69 records.
http://www-1.ibm.com/support/docview.wss?uid=isg1OW45020 Don Imbriale -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Edward Jaffe Sent: Thursday, December 21, 2006 6:07 PM To: [email protected] Subject: SMF Type 19 and IPL Hang If you collect SMF Type 19 records, beware that an SMF-initialization-time LSPACE request is issued for every volume connected to the system. If SYSVTOC.volid is held by another system for any significant period of time, an IPLing system will appear to be "stuck". This happened to us and we had to wait over half an hour for a full-volume dump (occurring on another system) of a 60K cylinder DASD to finish before SMF would initialize and the IPL could continue. The contention looked like this: ISG343I 08.05.18 GRS STATUS FRAME LAST F E SYS=MVS70 S=SYSTEMS SYSVTOC TIVSM4 SYSNAME JOBNAME ASID TCBADDR EXC/SHR STATUS MVS70 DFHSM70 0026 00BA2E88 EXCLUSIVE OWN MVS60 SMF 0018 00BFD0C0 EXCLUSIVE WAIT IBM's suggestion for a fix/workaround/solution? Don't collect SMF Type 19 records. :-( *********************************************************************** Bear Stearns is not responsible for any recommendation, solicitation, offer or agreement or any information about any transaction, customer account or account activity contained in this communication. *********************************************************************** ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html