Hello:

 

We have a configuration consisting of a LPAR1 and a LPAR5 on a Z800 at
our home site.

We have another Z800 at our DR site which is an exact clone of our home
site.

We replicate our disk image home to DR. 

 

When doing DR tests we spend a lot of time dinking around getting the DR
configuration right; network the greatest concern.

 

Was RTFMing and think may have a way around the dinking.

 

Would take our current IOCP with our LPAR1/LPAR5 configuration which is
identical home and DR and carve out a  LPARDR and then create a new IODF
with LPAR1, LPAR5, and LPARDR.

 

Once loaded may now specify SYSDEF LPARNAME(LPARDR) and specify IEASYSxx
members to load.

 

Comments, advice, suggestions please.

 

 

John Donnelly

z/OS Systems Services

National Semiconductor

Corporation

2900 Semiconductor Drive

Santa Clara, CA 95051

PH: 408-721-5640