Hello:
We have a configuration consisting of a LPAR1 and a LPAR5 on a Z800 at our home site. We have another Z800 at our DR site which is an exact clone of our home site. We replicate our disk image home to DR. When doing DR tests we spend a lot of time dinking around getting the DR configuration right; network the greatest concern. Was RTFMing and think may have a way around the dinking. Would take our current IOCP with our LPAR1/LPAR5 configuration which is identical home and DR and carve out a LPARDR and then create a new IODF with LPAR1, LPAR5, and LPARDR. Once loaded may now specify SYSDEF LPARNAME(LPARDR) and specify IEASYSxx members to load. Comments, advice, suggestions please. John Donnelly z/OS Systems Services National Semiconductor Corporation 2900 Semiconductor Drive Santa Clara, CA 95051 PH: 408-721-5640 Email: [EMAIL PROTECTED] ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html