On Thu, 4 Jan 2007 14:52:02 -0500, Jim Mulder <[EMAIL PROTECTED]> wrote:

>...
>  The routing to WTO SSI function routines is done by SSI, not
>Console, so the SYSOPS CTRACE will not help you a snapshot
>after each function routine. Your choices would be:
>
>1. SLIP IF,A=TRACE  in IEFJRASP with a DATA filter on the SSI
>   function code.  IEFJRASP is OCO, so you would need assistance from
>   MVS SSI Level 2 to construct the SLIP.
>
>2. Write an IEFJFRQ exit.  This is documented in the
>   "MVS Istallation Exits" manual.
>...

I suspect there is a 1.5 option also.  Set a SLIP trace on a dummy 
IEFJRASP since the exit is documented.  It's been a long time since I've
set up a SLIP trace.  (Last time was looking for the Unix dirty bits in
TCBs.  Honestly!  It was.) 

I was going to say, given your response, that maybe I'd just wait until
NetView lvl 2 suggested what I do to debug this.  But they just did.  They
just suggested a COMP=SYSOPS CTRACE.  <sigh> 

That would give me the WQE after the SSIs are done with it?  Not exactly
what I was hoping for.  

Pat O'Keefe

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to