On Thu, 4 Jan 2007 14:52:02 -0500, Jim Mulder <[EMAIL PROTECTED]> wrote:
>... > The routing to WTO SSI function routines is done by SSI, not >Console, so the SYSOPS CTRACE will not help you a snapshot >after each function routine. Your choices would be: > >1. SLIP IF,A=TRACE in IEFJRASP with a DATA filter on the SSI > function code. IEFJRASP is OCO, so you would need assistance from > MVS SSI Level 2 to construct the SLIP. > >2. Write an IEFJFRQ exit. This is documented in the > "MVS Istallation Exits" manual. >... I suspect there is a 1.5 option also. Set a SLIP trace on a dummy IEFJRASP since the exit is documented. It's been a long time since I've set up a SLIP trace. (Last time was looking for the Unix dirty bits in TCBs. Honestly! It was.) I was going to say, given your response, that maybe I'd just wait until NetView lvl 2 suggested what I do to debug this. But they just did. They just suggested a COMP=SYSOPS CTRACE. <sigh> That would give me the WQE after the SSIs are done with it? Not exactly what I was hoping for. Pat O'Keefe ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html