No, if noscratch was specified and the gdg wrapped around then the dataset 
would not be able to roll in.
 
Esmie, how many catalog entries exist under the base gdg name? Just do a 3.4 
display under ispf. 

________________________________

From: John Kington [mailto:[EMAIL PROTECTED]
Sent: Tue 1/16/2007 8:36 AM
To: [email protected]
Subject: Re: CATALOG ERROR



>Do you have noscratch specified in the GDG define? It should be scratch to
have the oldest gdg automatically roll off to allow the next generation to
be catalogued.

The listcat should look as follows:

ATTRIBUTES
  LIMIT-----------------10     SCRATCH          NOEMPTY

David,
He must have had scratch in the GDG or the job would not have had a
problem cataloging the new GDS. I do not have DFHSM so I don't
know how management class attributes work in this situation.
Regards,
John

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to