The following scenario:
3 CPCs connected FICON switch (12 chpids per CPC), the switch is connected to another switch on remote site (only 6 FICON ports), several tape drive CUs (12 chpids total) connected to the remote switch.
Drawing:
3CPC--SWCH1-----SWCH2--TAPE

Number of links between switches cannot be increased. I need to access whole 12 drives from every CPC.

In the times of ESCON directors it was simply impossible , since one of the "hops" had to be static. AFAIK in FICON world both switches can be dynamic.

Can I put those 36 paths (12 from CU to each of 3 CPCs) to 6 links between the sites ? Im' aware I of bandwith reduction possibility.

--
Radoslaw Skorupka
Lodz, Poland

----------------------------------------------------------------------