David,
   
  I included the reorg just to test and see if the job runs okay.  The reorg of 
the MCDS is run weekly.  The freespace is 0,0 .  Below is the present set up of 
the MCDS.
   
  DEFINE CLUSTER -                                
   (NAME(AM2.MCDS) VOLUME(PLAN01) -             
       CYLINDER(3300 0) FILE(HSMMCDS) -         
       RECORDSIZE(435 2040) FREESPACE(0 0) -    
       SPEED BUFFERSPACE(530432) -              
       INDEXED KEYS(44 0) SHAREOPTIONS(3 3) -   
       UNIQUE NOWRITECHECK)  -                  
   DATA  (NAME(AM2.MCDS.DATA) CISZ(12288) ) -   
   INDEX (NAME(AM2.MCDS.INDEX) CISZ(2048) )     
   
  Would you foresee any problems when switching over to VSAM EXTENDED?


"O'Brien, David W. (NIH/CIT) [C]" <[EMAIL PROTECTED]> wrote:
  Willie,

"- Perform tests : i.e. migrate and recall. Perform the regorg."

Why are you performimg a re-org in your last step? The repro should populate 
the file in sequential order so that no re-org is necessary at that point.

What is the freespace value for this MCDS? This could be contributing to the 
problem.







----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


 
---------------------------------
Food fight? Enjoy some healthy debate
in the Yahoo! Answers Food & Drink Q&A.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html