On Monday 09 April 2007 12:26, John P Donnelly wrote:
> Moving V1R4 to V1R7 and getting the following on V1R7:
>
>
Return code 10 from the ADR374 Message says;
10 Invalid parameters passed in JCL. The following are the probable
reasons:
t SYSIN/SYSOUT data set
t DISP=MOD coded for the output data set
t DISP=SHR coded for the output data set
t BLKSIZE less than 7892 bytes
t DSORG other than PS
t BUFNO specified.
Do one of these apply?
<snip>
--
Mark Jacobs
Time Customer Service
Tampa, FL
-----------------------------