On Sat, 19 May 2007 17:02:52 +0200, R.S. wrote:

>
>1. I don't know whether STP solution can use 'atomic clock' as a time
>reference. AFAIK, it was asked on the list, but noone answered.
>2. (**) Two sysplex timers are required, because of redundancy. AFAIK if
>you loose ETR (sysplex timer or timer connection), then all your systems
>will end with wait state.
>

We only have one timer. We only use it to keep the clocks relatively close to 
reality and to keep them consistent across the enterprise.

Also, if you lose the timer, you can recover and run without it. It takes a few 
seconds for error recovery and to present the option on the console. By this 
time, most of our communication sessions time out, so we've got some work to 
do to get everything reconnected. But batch JOBs continue to run and 
everything else runs just fine too once you restart all your VTAM applications 
and such.

----------------------------------------------------------------------