On Tue, 29 May 2007 14:51:48 -0400, Mark Jacobs <[EMAIL PROTECTED]>
wrote:

>We have a vendor product, no longer under support, that issues operator
>commands when it starts up. When we have a zOS 1.8 system in the sysplex
>the start commands fail with this message;
>
>IEE345I START AUTHORITY INVALID, FAILED BY MVS
>
>When the zOS 1.8 system is removed from the sysplex the start command is
>successful. The issuing system is zOS 1.7.
>
>I know that these commands are being issued with a one-byte console id
>since they show up in the DISPLAY OPDATA, TRACKING report.
>
>Is there anything that I can do to get it to work or are we SOL.

Can you post the entire text of the IEE345I message line from SYSLOG, the
CONSOLxx defnition for the console named on that line and the D C,CN=
results for that console from that system?

I suspect that the program is using some console id/name scavenged from some
control block and that the console no longer has the MASTER attribute.

Scott Fagen
z/OS Core Technology Design
IBM Poughkeepsie

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to