>> Tom Kelman wrote:
>

>> > Then why when I try to edit or browse an SMF file on disk
(LRECL=32760)
>> > do I get the message "Invalid Record Length".  I just tried it.

>>>
>> John Kalinich wrote:
>> 
>> Maybe it is variable spanned format?
>> 
>> Regards,
>> John K
>> 

>Yes, it is VBS.  Then why doesn't the error message say "Invalid
Format"
>instead of "Invalid Record Length"?  Maybe this was the problem with
the original posters file.  It was actually an >invalid RECFM.


You're not trying to edit the MANx files are you? Those are VSAM and
would give you the error that you are seeing. 


Jon L. Veilleux
[EMAIL PROTECTED]
(860) 636-2683 

This e-mail may contain confidential or privileged information. If
you think you have received this e-mail in error, please advise the
sender by reply e-mail and then delete this e-mail immediately.