>> >> Tom Kelman wrote: > >> > Then why when I try to edit or browse an SMF file on disk (LRECL=32760) >> > do I get the message "Invalid Record Length". I just tried it.
>>> >> John Kalinich wrote: >> >> Maybe it is variable spanned format? >> >> Regards, >> John K >> >Yes, it is VBS. Then why doesn't the error message say "Invalid Format" >instead of "Invalid Record Length"? Maybe this was the problem with the original posters file. It was actually an >invalid RECFM. You're not trying to edit the MANx files are you? Those are VSAM and would give you the error that you are seeing. Jon L. Veilleux [EMAIL PROTECTED] (860) 636-2683 This e-mail may contain confidential or privileged information. If you think you have received this e-mail in error, please advise the sender by reply e-mail and then delete this e-mail immediately. Thank you. Aetna ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html