The operator responded to the message as below,
* IEA888A LOCAL DATE=2007.240,CLOCK=08.43.10 REPLY U, OR UTC/LOCAL TIME
IEE600I REPLY TO 00 IS;DATE=2008.001,CLOCK=08.45.00
IEA888A UTC DATE=2007.240,CLOCK=08.44.07
* IEA888A LOCAL DATE=2008.001,CLOCK=08.45.00 REPLY U, OR UTC/LOCAL
TIME
Thanks to all those who responded. I could solve the problem by selecting
sysplex timer and setting an timer offset in the image profile of the LPAR.
Deactivated/activated test LPAR, IPL-ed the system with CLOCKxx
OPERATOR NOPROMPT
USS and TSO now both show future date.
Regards
Arun
---------------------------------