The operator responded to the message as below,
   
   *   IEA888A LOCAL DATE=2007.240,CLOCK=08.43.10  REPLY U, OR UTC/LOCAL  TIME  
                                                               
  IEE600I REPLY TO 00 IS;DATE=2008.001,CLOCK=08.45.00                  
  IEA888A UTC   DATE=2007.240,CLOCK=08.44.07                           
 *   IEA888A LOCAL DATE=2008.001,CLOCK=08.45.00  REPLY U, OR UTC/LOCAL 
  TIME                                                                 
   
  Thanks to all those who responded. I could solve the problem by selecting 
sysplex timer and setting an timer offset in the image profile of the LPAR. 
Deactivated/activated test LPAR, IPL-ed the system with CLOCKxx
   
  OPERATOR NOPROMPT
   
  USS and TSO now both show future date.
   
  Regards
  Arun


       
---------------------------------