The advice I've heeded for years is NOT to perform STORE STATUS for standalone dump because MVS itself sets a flag that requests STORE STATUS on the next IPL in the same LPAR. So manual action is not only unnecessary, but you might inadvertently get status stored from SAD itself rather than from the running OS. That would be appropriate only if you're trying to debug standalone dump code.
.
.
JO.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
[EMAIL PROTECTED]
George Rodriguez
<[EMAIL PROTECTED]
EACH.K12.FL.US> To
Sent by: IBM [email protected]
Mainframe cc
Discussion List
<[EMAIL PROTECTED] Subject
.EDU> Stand-Alone Dump Process
08/31/2007 09:30
AM
Please respond to
IBM Mainframe
Discussion List
<[EMAIL PROTECTED]
.EDU>
Have any of you ever heard that a Store-Status is NOT needed for dump
taking? Does anyone have a stand-alone dump procedure that they would be
willing to share?
TIA,
George Rodriguez
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html