Is the model type that is returned from the D M=CPU command correct on that system?
I would think (just a logical guess - so proceed at your own risk) that if you issued the CF CPU(03),OFFLINE it would go offline and the status of the CPU in the D M=CPU would change from + to N. You probably wanted to CF CPU(03),OFFLINE prior to conversion. I know that is part of the procedure when removing engines after using o/oCUoD. Don't forget to change your activation profile on the HMC to the correct number of initial CPs and deactivate/activate your LPAR(s) when you get a chance. Regards, Steve -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Hal Merritt Sent: Tuesday, September 11, 2007 4:16 PM To: [email protected] Subject: Concurrent Upgrade Puzzlement. We just upgraded our z/890 from a model 450 to a model 370. That translates to one less CP, but the overall power increases from 97 to 158 MSU's. There was no requirement for an outage (IPL, POR) given, so we elected to do it concurrently. (We IPL/POR only when we have to.) There was no visible event as the change took effect. RMF displays seem to be all in sync. However, a D M=CPU command comes back with different results on one LPAR. That one still shows four CP's online. Any ideas? Thanks... NOTICE: This electronic mail message and any files transmitted with it are intended exclusively for the individual or entity to which it is addressed. The message, together with any attachment, may contain confidential and/or privileged information. Any unauthorized review, use, printing, saving, copying, disclosure or distribution is strictly prohibited. If you have received this message in error, please immediately advise the sender by reply email and delete all copies. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html ============================================================================== Please access the attached hyperlink for an important electronic communications disclaimer: http://www.credit-suisse.com/legal/en/disclaimer_email_ib.html ============================================================================== ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html