Hal,
what is in your LPAR definition ? If you have 4 CPs there, it
dispatches four logical CPs on three physical CPs. Not a good idea.

Marian

On 9/11/07, Hal Merritt <[EMAIL PROTECTED]> wrote:
> We just upgraded our z/890 from a model 450 to a model 370. That
> translates to one less CP, but the overall power increases from 97 to
> 158 MSU's. There was no requirement for an outage (IPL, POR) given, so
> we elected to do it concurrently. (We IPL/POR  only when we have to.)
>
> There was no visible event as the change took effect. RMF displays seem
> to be all in sync.
>
> However, a D M=CPU command comes back with different results on one
> LPAR. That one still shows four CP's online. Any ideas?
>
>
> Thanks...
>
> NOTICE: This electronic mail message and any files transmitted with it are 
> intended exclusively
> for the individual or entity to which it is addressed. The message, together 
> with any attachment, may contain confidential and/or privileged
> information. Any unauthorized review, use, printing, saving, copying, 
> disclosure
> or distribution is strictly prohibited. If you have received this message in 
> error, please immediately
> advise the sender by reply email and delete all copies.
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html
>

----------------------------------------------------------------------