Jacky,

For those datasets that won't recall, see if you have a backup.  If you
do, see if you can recover newname the datasets.  Then hdelete the
originals and rename the newnames to the original name.  If you are able
to recover all the files off the tape, then recycle force the tape.
However, if you can't get all the data off the tape, determine if the
remaining data is vital.  If it is not, then recycle force the tape.  If
the data is vital, the see if it can be recreated.  Otherwise, its off
to Tucson with your tape.

Terry Traylor
charlesSCHWAB
TIS Mainframe Storage Management
Remedy Queue: tis-hs-mstg
(602) 977-5154 

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Jacky Bright
Sent: Monday, January 07, 2008 11:53 AM
To: [email protected]
Subject: Problem while recalling few datasets

Hi,

I am getting following error while recalling few datasets. But few
datasets recalls are successful.


IOS000I 882A,E3,EQC,07,0E00,,**,,DFHSM  657

 10482035000000206011(B310000102005015)0000(500007FF)CE3F1D9B13140A00

IEC512I I/O ERR 882A,AT3728,,DFHSM,DFHSM,DFHSM.HMIGTAPE.DATASET

IEC502E R 882A,,DFHSM,DFHSM


ARC1001I ACIS.C008MRGE.CUCPR004.CASH.G0716V00  RECALL FAILED, RC=0035,
ARC1001I (CONT.) REAS=0000 ARC1135I ERROR OPENING INPUT DATA SET DURING
RECALL/RECOVERY
***

Any idea on this. This is urgent as few production datasets are not
getting recalled.



JAcky

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send
email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search
the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to