Hi George,
Thanks for your information. While I use the Freeze & run command, all path
are deleted from our primary site.
The primary site disk are in "SUSPEND(A)" and secondary site disk are in
"DUPLEX".
Firstly, I need to establish the path then RECOVERY the secondary site
DUPLEX status to SIMPLEX, Finally, I use the mode(failback) to RESYNC all
changed bit from primary site to secondary site.

Is it correct steps??? or I have some wrong ..
Why? the primary site suspend use failback and second site suspend use
MODE(RESYNC)??

Best regards
Tommy



On 2/5/08, [EMAIL PROTECTED] <[EMAIL PROTECTED]> wrote:
>
> On Feb 4, 10:12 pm, [EMAIL PROTECTED] (Tommy Tsui) wrote:
> > hi all,
> >
> >       I have a question on how to resync the change bit to remote site
> after
> > CGROUP FREEZE & RUN are executed.  Is it using MODE(RESYNC) or FAILBACK
> or
> > others?
> >
> > any comment will be appreciated
> >
> > Tommy
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
> > Search the archives athttp://bama.ua.edu/archives/ibm-main.html
> Hi Tommy,
> You would normally use MODE(RESYNC). Failback is used if a Failover
> was done. The way to tell is to check the status of the secondary
> device. If it is SEC-SUSP, use MODE(RESYNC) whereas if it is PRI-SUSP,
> use FAILBACK.
>
> Regards, George Kozakos
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html