Ted MacNEIL wrote:
1. Nothing runs in the WLM address space.
To clarify, WLM code runs in the WLM address space. I just looked on a system IPLed Tuesday evening and see over 15 minutes of CPU charged to that one STC. There are even some ExCPs.
|ACTIVITY PHXHQ(MVS60) Paging 1 SIO 14 CPU 4/4 . |Command ===> . |Cmd JobName ExCP-Cnt CPU-Time ACPU-Time SrvClass Workload . |<-- --------/--------- -------- --------- -------- -------- . | WLM 272 15:41.87 15:41.87 SYSTEM SYSTEM . |IEE254I 14.02.45 IPLINFO DISPLAY 565 | SYSTEM IPLED AT 19.59.30 ON 02/05/2008 -- Edward E Jaffe Phoenix Software International, Inc 5200 W Century Blvd, Suite 800 Los Angeles, CA 90045 310-338-0400 x318 [EMAIL PROTECTED] http://www.phoenixsoftware.com/ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html