Ted MacNEIL wrote:
1. Nothing runs in the WLM address space.

To clarify, WLM code runs in the WLM address space. I just looked on a system IPLed Tuesday evening and see over 15 minutes of CPU charged to that one STC. There are even some ExCPs.

|ACTIVITY PHXHQ(MVS60)  Paging 1  SIO 14  CPU 4/4            .
|Command ===>                                                .
|Cmd JobName  ExCP-Cnt  CPU-Time ACPU-Time SrvClass Workload .
|<-- --------/--------- -------- --------- -------- -------- .
|    WLM            272 15:41.87 15:41.87  SYSTEM   SYSTEM   .

|IEE254I  14.02.45 IPLINFO DISPLAY 565
| SYSTEM IPLED AT 19.59.30 ON 02/05/2008

--
Edward E Jaffe
Phoenix Software International, Inc
5200 W Century Blvd, Suite 800
Los Angeles, CA 90045
310-338-0400 x318
[EMAIL PROTECTED]
http://www.phoenixsoftware.com/

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html