On Thu, 7 Feb 2008 16:27:19 -0600, Mark Zelden <[EMAIL PROTECTED]> wrote:


>I also took a console dump.   The service classes I saw were:
>
>TSO - Importance 3 with a percentile goal
>SYSTEM - fixed DP x'FF'
>SYSSTC - fixed DP x'FF'
>SYSSTC1 - fixed DP x'FF'
>SYSSTC2 - fixed DP x'FF'
>SYSSTC3 - fixed DP x'FF'
>SYSSTC4 - fixed DP x'FF'
>SYSSTC5 - fixed DP x'FF'
>SYSOTHER - discretionary
>
>SYSSTC1-SYSSTC5 are documented in the WLM planning manual as
>"provided for future z/OS and EWLM support".
>

Eeek... cut & paste strikes again.  All the SYSSYC classes run at
a fixed DP of x'FE'.  This should have read:

TSO - Importance 3 with a percentile goal
SYSTEM - fixed DP x'FF'
SYSSTC - fixed DP x'FE'
SYSSTC1 - fixed DP x'FE'
SYSSTC2 - fixed DP x'FE'
SYSSTC3 - fixed DP x'FE'
SYSSTC4 - fixed DP x'FE'
SYSSTC5 - fixed DP x'FE'