On Tue, 19 Feb 2008 02:11:27 +0800, Tommy Tsui wrote: >hi all, > >we found that many jobs abended with 878-04 after upgrade CPU from 2064 to >2094 (first day batch) . There are no error when runnng on 2064 machine. any >shop have this problem?? >Is there any control-block changed after upgrade CPU??/ > >any comment will be appreciated > >Many thanks > >tommy
Perhaps on your 2064, your DASD devices were defined LOCANY YES and on the 2094 they're defined LOCANY NO? Parameter/ Feature Value R Description LOCANY Yes UCB can reside in 31 bit storage Brian ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html