On Tue, 19 Feb 2008 02:11:27 +0800, Tommy Tsui wrote:

>hi all,
>
>we found that many jobs abended with 878-04 after upgrade CPU from 2064 
to
>2094 (first day batch) . There are no error when runnng on 2064 machine. 
any
>shop have this problem??
>Is there any control-block changed after upgrade CPU??/
>
>any comment will be appreciated
>
>Many thanks
>
>tommy

Perhaps on your 2064, your DASD devices were defined LOCANY YES and on 
the 2094 they're defined LOCANY NO?

Parameter/                                                    
Feature    Value            R Description                     
LOCANY     Yes                UCB can reside in 31 bit storage

Brian

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to