I check with the IODF definition. All device are already in LOCANY YES, but some of our job does not code the region size on job step that means it will use the default. In our JES2 parm, the default region size is 1M.
On 2/19/08, Brian Peterson <[EMAIL PROTECTED]> wrote: > > On Tue, 19 Feb 2008 02:11:27 +0800, Tommy Tsui wrote: > > >hi all, > > > >we found that many jobs abended with 878-04 after upgrade CPU from 2064 > to > >2094 (first day batch) . There are no error when runnng on 2064 machine. > any > >shop have this problem?? > >Is there any control-block changed after upgrade CPU??/ > > > >any comment will be appreciated > > > >Many thanks > > > >tommy > > Perhaps on your 2064, your DASD devices were defined LOCANY YES and on > the 2094 they're defined LOCANY NO? > > Parameter/ > Feature Value R Description > LOCANY Yes UCB can reside in 31 bit storage > > Brian > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO > Search the archives at http://bama.ua.edu/archives/ibm-main.html > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html