>If JES2 is up, then:
>
>o Submit a job with:
>
>  - STEP1 IDCAMS ALTER NAME
>
>  - STEP2 IEFBR14 with DISP=OLD on the PROCLIB catenands.
>
>o The job waits on PROCLIB ENQ
>
>o Stop JES2
>
>o Start JES2
>
>o JES2 waits on PROCLIB ENQ
>
>o The RENAME job completes freeing the ENQs
>
>o JES2 allocates PROCLIB and continues.

In the above scenario, you would never get JES2 to shut down cleanly while a 
job is still executing.  (It would need to be an STC running SUBSYS=MASTER.)  
And, even if this did work, you better hope that the job is successful; else, 
you are left without the PROCLIB and JES2 won't start!

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to