On Sun, 27 Apr 2008 12:50:29 -0700, Skip Robinson <[EMAIL PROTECTED]>
wrote:

>I put this question to IBM recently and learned a difference between
>parallel sysplex (with CF) and basic sysplex (without). With CF supporting
>XCF, other systems are notified when one member is truly down. Without a
>CF, other systems *believe* a member is down but need operator
>confirmation.
>
>That difference matches our experience across the enterprise.
>

Is that true even with an SFM policy?  

--