We did this recently. Removed the old processor without moving the
structures before shutting down. 

We realized we'd seen this situation when going to DR so we ended up
deleting the CFRM datasets and reloading them with the new policy and
then ipling the sysplex. 

For us this was the cleanest and quickest solution.

Alan
-----Original Message-----
Subject: Cleanup a unconnected Coupling Facility

We migrated our 2094 to 2097 .
We prepared A new CFRM policy containing the new 2097 definition on the
two 
CF lpars, CF2 and CF3.
Now, after the migration we have CF3 defined on 2097 with active
structures, 
but CF2 has still definitions of the old structures and remained pending
with its 
2094 definition and with "NO SYSTEMS CONNECTED to this CF"

How can we CLEANUP the remaining Structures in CF2 so that the new 2097 
difinition will take place so that we will be able to use the CF ??

C. Jeret  Bank- Hapoalim T.A.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to