We did this recently. Removed the old processor without moving the structures before shutting down.
We realized we'd seen this situation when going to DR so we ended up deleting the CFRM datasets and reloading them with the new policy and then ipling the sysplex. For us this was the cleanest and quickest solution. Alan -----Original Message----- Subject: Cleanup a unconnected Coupling Facility We migrated our 2094 to 2097 . We prepared A new CFRM policy containing the new 2097 definition on the two CF lpars, CF2 and CF3. Now, after the migration we have CF3 defined on 2097 with active structures, but CF2 has still definitions of the old structures and remained pending with its 2094 definition and with "NO SYSTEMS CONNECTED to this CF" How can we CLEANUP the remaining Structures in CF2 so that the new 2097 difinition will take place so that we will be able to use the CF ?? C. Jeret Bank- Hapoalim T.A. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html