Just for the archive. IBM will open a APAR (SUG) and introduce a PREFIX= option to bypass the naming conflict.
Roland >At 18:14 -0400 on 05/08/2008, Rob Scott wrote about Re: IFAQUAA >layout for IFAQUERY: > >>Roland >> >>How about using "IFAQUAA QUAHDR=NO" >> >>The format of the header blocks is the same (although the name of >>the "offset to the first record" field is different- tsk tsk) >> >>An option available to IBM is to map the QUAHDR DSECT in an >>independent macro and then just invoke it from within xxxQUAA... > >Another solution since the mappings and names (except for that one >case) are the same is to have a global set symbol to say that the >section was already expanded and bypass the 2nd expansion. Also >define the "offset to the first record" field with both labels. I'm >assuming that the DSECT is a separate DSECT which uses a separate >USING not one that uses the base USING of the Macro and just jumps >over this section in the definitions. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html