Greg,

We've discovered the problem. 

First in the HMC hardware messages we've saw the chpid and unit address 
error.
Second we've found the control units and we have an incorrect definition in 
the alias unit address and we've changed for the next dynamic activacion iodf.
Like you say, it's a discrepancy between IOCDS and the storage configuration.

Kind regards

----------------------------------------------------------------------