I would expect message IXC457I to be issued when the new structure instance
is successfully allocated in a new CF.  What does that message say when the
structure in question is rebuilt into the CF that causes the health check to
complain.
 A structure with zero lists is bizarre.  Perhaps there was not enough space
in the CF to actually allocate it?  You might also look for message IXC463I,
or issue DISPLAY XCF,STR,STRNAME=xxx for the structure in question to see
what XCF has to say about it when it lives in the CF that causes the complaint.

----------------------------------------------------------------------