Mark, Bill:
I answer all your questions:
Normal CF for IXCPATH6: CF2
Other CF for IXCPATH6: CF1
<<What size does the CFRM policy specify for the IXCPATH6 structure? >>
In CF2:
POLICY INFORMATION:
POLICY SIZE : 117760 K
POLICY INITSIZE: N/A
POLICY MINSIZE : 0 K
FULLTHRESHOLD : 80
ALLOWAUTOALT : NO
REBUILD PERCENT: 1
DUPLEX : DISABLED
ALLOWREALLOCATE: YES
PREFERENCE LIST: CF2 CF1
ENFORCEORDER : NO
EXCLUSION LIST : IXCPATH3
In CF1:
POLICY INFORMATION:
POLICY SIZE : 117760 K
POLICY INITSIZE: N/A
POLICY MINSIZE : 0 K
FULLTHRESHOLD : 80
ALLOWAUTOALT : NO
REBUILD PERCENT: 1
DUPLEX : DISABLED
ALLOWREALLOCATE: YES
PREFERENCE LIST: CF2 CF1
ENFORCEORDER : NO
EXCLUSION LIST : IXCPATH3
<<What is the actual allocated size of the structure?>>
<<How many list entries does the structure have?>>
In CF1:
ACTIVE STRUCTURE
----------------
ALLOCATION TIME: 06/27/2008 08:53:30
CFNAME : CF1
COUPLING FACILITY: 002094.IBM.51.00000007ED1A
PARTITION: 04 CPCID: 00
ACTUAL SIZE : 118272 K
STORAGE INCREMENT SIZE: 512 K
ENTRIES: IN-USE: 1 TOTAL: 25798, 0% FULL
ELEMENTS: IN-USE: 31 TOTAL: 25791, 0% FULL
PHYSICAL VERSION: C29B0A6C EA750DE6
LOGICAL VERSION: C29B0A6C EA750DE6
SYSTEM-MANAGED PROCESS LEVEL: NOT APPLICABLE
DISPOSITION : DELETE
ACCESS TIME : 0
MAX CONNECTIONS: 32
Ñ CONNECTIONS : 5
In CF2:
ALLOCATION TIME: 06/27/2008 08:56:32
CFNAME : CF2
COUPLING FACILITY: 002094.IBM.51.00000007ED2A
PARTITION: 08 CPCID: 00
ACTUAL SIZE : 118272 K
STORAGE INCREMENT SIZE: 512 K
ENTRIES: IN-USE: 1 TOTAL: 25798, 0% FULL
ELEMENTS: IN-USE: 47 TOTAL: 25791, 0% FULL
PHYSICAL VERSION: C29B0B1A 820EE343
LOGICAL VERSION: C29B0B1A 820EE343
SYSTEM-MANAGED PROCESS LEVEL: NOT APPLICABLE
DISPOSITION : DELETE
ACCESS TIME : 0
MAX CONNECTIONS: 32
Ñ CONNECTIONS : 5
<<What are the CFLEVELs of the two CFs?>>
15
CF Name Total Space Free Space Free% V Lvl
-------- ----------- ---------- ----- - ---
CF1 957440 K 769536 K 80.37 Y 15
CF2 957440 K 454656 K 47.49 Y 15
<<For how many systems is the primary sysplex couple data set formatted?>
12
SYSPLEX COUPLE DATA SETS
PRIMARY DSN: SYS1.SYSPLEX0.XCF.CDS01
VOLSER: PLX004 DEVN: 03EB
FORMAT TOD MAXSYSTEM MAXGROUP(PEAK) MAXMEMBER
(PEAK)
06/24/2008 14:50:17 12 50 (36) 123 (12)
ADDITIONAL INFORMATION:
ALL TYPES OF COUPLE DATA SETS ARE SUPPORTED
GRS STAR MODE IS SUPPORTED
ALTERNATE DSN: SYS1.SYSPLEX0.XCF.CDS02
VOLSER: PLX005 DEVN: 0434
FORMAT TOD MAXSYSTEM MAXGROUP MAXMEMBER
06/24/2008 14:49:01 12 50 123
ADDITIONAL INFORMATION:
ALL TYPES OF COUPLE DATA SETS ARE SUPPORTED
GRS STAR MODE IS SUPPORTED
<<When you used CFSizer, what did you specify for the ClassLen input?>>
Nothing. We use this job:
//CFSIZER JOB (S01),'SISTEMAS',CLASS=A,MSGCLASS=X,NOTIFY=&SYSUID,
// MSGLEVEL=1
//S1 EXEC PGM=SIZER
//STEPLIB DD DSN=SYS2.BATCH.LOADAUTH,DISP=SHR
//SYSPRINT DD SYSOUT=*
//SYSOUT DD SYSOUT=*
//SYSOUT DD SYSOUT=*
<<I would expect message IXC457I to be issued when the new structure
instance is successfully allocated in a new CF. What does that message say
when the structure in question is rebuilt into the CF that causes the health
check to complain.>>
The message appears:
IXC457I REBUILT STRUCTURE IXCPATH6 ALLOCATED 876
WITH 140 LISTS WHICH SUPPORTS FULL SIGNALLING CONNECTIVITY
AMONG 12 SYSTEMS AND UP TO 25789 SIGNALS
<<Perhaps there was not enough space in the CF to actually allocate it? >>
No Mark. There's too much space:
CF Name Total Space Free Space
-------- ----------- ----------
CF1 957440 K 769536 K
CF2 957440 K 454656 K
<<You might also look for message IXC463I>>
The message doesn't appear in any system
<<issue DISPLAY XCF,STR,STRNAME=xxx for the structure in question to see
what XCF has to say about it when it lives in the CF that causes the
complaint>>
The display is showed above. The rest of it is showed below:
CONNECTION NAME ID VERSION SYSNAME JOBNAME ASID STATE
---------------- -- -------- -------- -------- ---- ----------------
SIGPATH_0100063F 01 00010006 LNA2 XCFAS 0006 ACTIVE
SIGPATH_02000641 02 00020005 LNA4 XCFAS 0006 ACTIVE
SIGPATH_03000642 03 00030007 LNA1 XCFAS 0006 ACTIVE
SIGPATH_04000643 04 00040006 DESA XCFAS 0006 ACTIVE
SIGPATH_05000640 05 00050033 REAL XCFAS 0006 ACTIVE
DIAGNOSTIC INFORMATION: STRNUM: 00000011 STRSEQ: 00000000
MANAGER SYSTEM ID: 00000000
EVENT MANAGEMENT: POLICY-BASED
Kind regards
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html