I've heard about a couple of things that can really slow an IPL down.
One is an ESCON channel connected to nothing or a inop device. NIP (or
somebody) will wait a very long time to see if it will come active. 

If there has been hardware microcode updates, the chp does not actually
load the new microcode until a live LPAR tries to touch it. That can
take a very long time. Worse if the chp is not connected to a live
device. 

Try identifying dead or chp's and deactivate via the SE. 

Also expect long delays the first time a chp is used, even to an
existing device. That scar is still fresh :-)   

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Stephen Wolf
Sent: Wednesday, July 16, 2008 2:34 PM
To: [email protected]
Subject: IODF change causes next IPL to "hang"

Hello List,

Are system is a 2096 U03 with three LPARs but no sysplex.  Two LPARs are

production, one at z/OS 1.4 and a small one at z/OS 1.7. The current
IODF is 
a version 5 level.

This weekend I activated a new IODF on the 1.4 system using the HCD
dialogs 
which completed successfully. I did not do an activate on the 1.7  We
then 
IPLed the 1.4 system and it just waited.  The NIP console was not
activated 
and there was not a hard wait. I brought up my rescue system and changed

the IODF back to the old one and the 1.4 system IPLed ok.  

 The 1.7 system complained about the new UCBs when I did the activate
but 
it kept running.

We have done a IODF change before but at that time only the 1.4 LPAR was

active.

DO I need to do a software IODF change on the 1.7 LPAR before I do the
IODF 
on the 1.4 system.

Regards,

Steve Wolf
Rockwell Automation
414-382-4308

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

NOTICE: This electronic mail message and any files transmitted with it are 
intended
exclusively for the individual or entity to which it is addressed. The message, 
together with any attachment, may contain confidential and/or privileged 
information.
Any unauthorized review, use, printing, saving, copying, disclosure or 
distribution 
is strictly prohibited. If you have received this message in error, please 
immediately advise the sender by reply email and delete all copies.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to