Have you asked the outside business to code dcb info in the process?

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Patrick O'Keefe
Sent: Tuesday, August 05, 2008 7:24 PM
To: [email protected]
Subject: STOPX37 & SMS loop

Has anybody using STOPX37 seen a problem where it gets in a loop
fighting with SMS over an insufficient space condition?   Anybody
have suggestions on how to avoid it?

Details:
A process is submitted via CONNECT:Direct (aka NDM) specifying SMS 
STORCLAS, MGMTCLAS, and DATACLAS  that result in selection of
volumes with too little space for the dataset being transfered. 
1. SMS says
IGD17272I VOLUME SELECTION HAS FAILED FOR INSUFFICIENT SPACE 
FOR DATASET ... 

2. STOPX37 says 
SVM4000I ...  ATTEMPTING SPACPRIM FOR ...

3.  SMS repeats indefinitely
IGD17272I VOLUME SELECTION HAS FAILED FOR INSUFFICIENT SPACE 
FOR DATASET ... 

Is there some way to cause a hard failure in situations like this?

I don't think CONNECT:Direct is significant in this except that 
this request is coming from an outside business partner.  We have 
absolutely no control over the size of the dataset or SMS parms 
specified.  

BTW, SMS and STOPX37 are way out of my areas of responsibility
and expertise.   I'm going to have to convey any suggestions to 
others that don't read IBM-Main.   Don't assume comprehension
on my part.

Pat O'Keefe

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


------------------------------------------------------------------------------
NOTICE:  This electronic mail message and any attached files are confidential.  
The information is exclusively for the use of the individual or entity intended 
as the recipient.  If you are not the intended recipient, any use, copying, 
printing, reviewing, retention, disclosure, distribution or forwarding of the 
message or any attached file is not authorized and is strictly prohibited.  If 
you have received this electronic mail message in error, please advise the 
sender by reply electronic mail immediately and permanently delete the original 
transmission, any attachments and any copies of this message from your computer 
system. Thank you.

==============================================================================

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to