Hi,

Two more OEM issues identified one currently unresolved not supporting
z/OS 1.9 with LCCA/PCCA > 16M.

#1 
DBT V6100 ABEND 0C4 The DBT Group, Inc. http://www.dbtgroup.com 
No resolution currently provided 

#2 
PHOENIX and PREFERENCE GSPCLEAR UTILITY ABEND 0C4 Sum Total Systems 
S791010

PHOENIX         7.9.1
PREFERENCE      7.9.1
PTF Number:     S791010

DATE:           09/04/2008

Applicability:  All PHOENIX and PREFERENCE Clients

Problem:        With the release of z/OS 1.9 the PCCA control block
                can optionally be moved about the 16 Meg line.  If
                you have the PCCA control block moved above the
                16 Meg line, this zap must be applied for
                PHOENIX/PREFERENCE to be compatible with this change.

Prerequisites:  None.

Coreq:          Apply this PTF, PTF S791007 and PTF S791008
                if you are using our CICS interface.



        Best Regards, 

                Sam Knutson, GEICO 
                System z Performance and Availability Management 
                mailto:[EMAIL PROTECTED] 
                (office)  301.986.3574              