On Fri, 31 Oct 2008 11:09:19 -0400, Richards, Robert B.
<[EMAIL PROTECTED]> wrote:

>We are getting ready to turn on SMF logstream processing. I took a quick
>look at the archives and haven't seen any new entries for the last six
>months.
>
> 
>
>Does anyone know the current status of the "date card" issue as it
>relates to record extraction?  We are z/OS 1.9 going to z/OS 1.10 in
>early 2009, if that matters.
>
> 
>
>TIA,
>
> 
>
>Bob 
>
> 
>
>---------------------------------------------------------
>
>Robert B. Richards    (Bob)               
>
>US Office of Personnel Management
>
>1900 E Street NW     Room: BH04L               
>
>Washington, D.C.  20415                  
>
>Phone: (202) 606-1195                      
>
>Email: [EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]>
>
>


Here are some related links, both the IBM white paper and also info about
CA's solution, CA SMF Director, which can address the challenges on
duplicate data dumping and data-extraction from the SMF logstream(s).

Scott Barry
SBBWorks, Inc.

IBM white paper:
http://ibm.com/support/techdocs/atsmastr.nsf/WebIndex/WP101130

Cheryl Watson's SHARE prez, mentioning SMF Logger (foil 21):
http://www.watsonwalker.com/PR080229.pdf

CA Advisor Series, discussion on SMF Logger Challenges - 
Streaming Without Screaming: CA SMF Director and the System Logger:
http://www.ca.com/us/products/collateral.aspx?cid=178381

CA SMF Director product info:
http://ca.com/files/ProductBriefs/smf_director_product_brief_us.pdf

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html