On Thu, 13 Nov 2008 08:46:24 -0600, Martin Kline <[EMAIL PROTECTED]> wrote:
>I prefer predictability... > >Yes, of course the systems must stay up, and the data sets must be moved. >Both must occur, so it is not a matter of choice. That being the case, since >the only 'officially' recommended solution is to risk a major outage, I decline to >follow convention. > >Alternative 1: Does anyone have thoughts about using DSS or another utility >to make an exact copy of the linklist library on another volume, such that the >internal TTRs will remain the same? I would expect this to allow LLA to read >the wrong data sets but get the right information in its tables. I wouldn't consider this. >Alternative 2: Disable LLA until the next IPL > >Alternative 3: Wait to recatalog the data sets until immediately before the >next scheduled IPL. Alternative 4: Remove this data set from LLA management Alternative 5: Copy the data set to the new location with a new name. Update Parmlib to reflect the new name. -- Tom Marchant ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html