On Sun, 8 Feb 2009 15:10:21 -0600, Tom Marchant wrote:
>>
>>>  r 00,'DATE=yyyy.ddd,CLOCK=hh.mm.ss,UTC|GMT'
>>>
>>Does specifying UTC on this command actually adjust the value
>>that will be returned by the TIME macro with the UTC/GMT option?
>
>This is not a command.  It is the reply to message IEA888A, which is issued
>if PROMPT is specified in CLOCKxx.  Yes, it does cause the TOD clock as seen
>by this LPAR to be set.
>
Ah, I see.  Then an IPL is necessary to adjust the clock.
Usually undesirable.