Hi Gary
No this is all I get out.
IEA247I USING IEASYSP2 FOR z/OS 01.10.00 HBB7750
ISG313I SYSTEM IS JOINING A GRS STAR COMPLEX. RING CONFIGURATION
KEYWORDS IN
GRSCNF00 ARE IGNORED.
IEA598I TIME ZONE = E.00.00.00
IXL157I PATH 01 IS NOW OPERATIONAL TO CUID: 0001
COUPLING FACILITY SIMDEV.IBM.EN.0000000CFCC1
PARTITION: 00 CPCID: 00
IXL157I PATH 02 IS NOW OPERATIONAL TO CUID: 0001
COUPLING FACILITY SIMDEV.IBM.EN.0000000CFCC1
PARTITION: 00 CPCID: 00
IXL157I PATH 03 IS NOW OPERATIONAL TO CUID: 0003
COUPLING FACILITY SIMDEV.IBM.EN.0000000CFCC2
PARTITION: 00 CPCID: 00
IXL157I PATH 04 IS NOW OPERATIONAL TO CUID: 0003
COUPLING FACILITY SIMDEV.IBM.EN.0000000CFCC2
PARTITION: 00 CPCID: 00
IXC454I SIGNALLING CONNECTIVITY CANNOT BE ESTABLISHED FOR SYSTEMS:
PLX1
IXC453I INSUFFICIENT SIGNALLING PATHS AVAILABLE TO ESTABLISH
CONNECTIVITY
IXC455D REPLY INTERVAL=NNN SECONDS TO RECHECK CONNECTIVITY OR R TO
REINITIALIZE XCF
Regards,
Stuart
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Diehl, Gary
Sent: 16 February 2009 16:33
To: [email protected]
Subject: Re: SYSPLEX Coupling
Stuart,
Have you been able to locate any IXC305I or IXC307I messages that might
indicate what failures are occurring when START PATH processing is
taking place? This might help pinpoint the source of the problem.
HTH,
Gary Diehl
Systems Administration
"One machine can do the work of fifty ordinary people. No machine can do
the work of one extraordinary person." -Elbert Hubbard
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO