Stuart Willis wrote: > Hi Mark > > Is the 2nd statement in the COUPLExx member > > >> COUPLE SYSPLEX(&SYSPLEX) >> CFRMPOL(WDSP2) <============= >> PCOUPLE(SYS1.XCF.CDS01) >> ACOUPLE(SYS1.XCF.CDS02) >> > > Regards, > Stuart > > >
Sorry, i didn't see it (old/bad eyes). Did you look in the ipl log to see if the CFRM policy was actually activated? > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On > Behalf Of Mark Jacobs > Sent: 16 February 2009 16:28 > To: IBM-MAIN@bama.ua.edu > Subject: Re: SYSPLEX Coupling > > Stuart Willis wrote: > >> Hi All >> >> New to this Listserv hope someone can help or point me in the correct >> direction. >> >> > > It doesn't look like yourCOUPLExx member has the CFRMPOL option in the > couple statement. This is used to point to the default CFRM policy if > this the the first time you are using these couple datasets. > > Mark Jacobs > > > >> We had an IBM P390 that was running VM and ZOS/1.5 in a 3 systems >> > close > >> coupled Sysplex and ran like a dream. >> >> That system has now been replaced by Z9 A02 processor running VM 5.3 >> > and > >> Zos/1.10 I have configured the Zos 1.10 systems the same as I did the >> > 1.5 > >> but I get the following. >> >> IEA247I USING IEASYSP2 FOR z/OS 01.10.00 HBB7750 >> > > >> ISG313I SYSTEM IS JOINING A GRS STAR COMPLEX. RING CONFIGURATION >> KEYWORDS IN >> GRSCNF00 ARE IGNORED. >> > > >> IEA598I TIME ZONE = E.00.00.00 >> > > >> IXL157I PATH 01 IS NOW OPERATIONAL TO CUID: 0001 >> > > >> COUPLING FACILITY SIMDEV.IBM.EN.0000000CFCC1 >> > > >> PARTITION: 00 CPCID: 00 >> > > >> IXL157I PATH 02 IS NOW OPERATIONAL TO CUID: 0001 >> > > >> COUPLING FACILITY SIMDEV.IBM.EN.0000000CFCC1 >> > > >> PARTITION: 00 CPCID: 00 >> > > >> IXL157I PATH 03 IS NOW OPERATIONAL TO CUID: 0003 >> > > >> COUPLING FACILITY SIMDEV.IBM.EN.0000000CFCC2 >> > > >> PARTITION: 00 CPCID: 00 >> > > >> IXL157I PATH 04 IS NOW OPERATIONAL TO CUID: 0003 >> > > >> COUPLING FACILITY SIMDEV.IBM.EN.0000000CFCC2 >> > > >> PARTITION: 00 CPCID: 00 >> > > >> IXC454I SIGNALLING CONNECTIVITY CANNOT BE ESTABLISHED FOR SYSTEMS: >> PLX1 >> IXC453I INSUFFICIENT SIGNALLING PATHS AVAILABLE TO ESTABLISH >> CONNECTIVITY >> IXC455D REPLY INTERVAL=NNN SECONDS TO RECHECK CONNECTIVITY OR R TO >> REINITIALIZE XCF >> > > >> I have gone over my configs searched the web for an answer but I can't >> > get it > >> to connect and it is driving me up the wall can any one help. >> >> Best Regards >> Stuart Willis >> >> my COUPLEXX parmlib Member >> COUPLE SYSPLEX(&SYSPLEX) >> CFRMPOL(WDSP2) >> PCOUPLE(SYS1.XCF.CDS01) >> ACOUPLE(SYS1.XCF.CDS02) >> DATA TYPE(CFRM) >> PCOUPLE(SYS1.XCF.CFRM.CDS01) >> ACOUPLE(SYS1.XCF.CFRM.CDS02) >> DATA TYPE(LOGR) >> PCOUPLE(SYS1.XCF.LOGR.CDS01) >> ACOUPLE(SYS1.XCF.LOGR.CDS02) >> DATA TYPE(ARM) >> PCOUPLE(SYS1.XCF.ARM.CDS01) >> ACOUPLE(SYS1.XCF.ARM.CDS02) >> DATA TYPE(SFM) >> PCOUPLE(SYS1.XCF.SFM.CDS01) >> ACOUPLE(SYS1.XCF.SFM.CDS02) >> DATA TYPE(BPXMCDS) >> PCOUPLE(SYS1.XCF.OMVS.CDS01) >> ACOUPLE(SYS1.XCF.OMVS.CDS02) >> DATA TYPE(WLM) >> PCOUPLE(SYS1.XCF.WLM.CDS) >> PATHIN >> STRNAME(IXCSTR1) >> PATHOUT >> STRNAME(IXCSTR1) >> PATHIN >> STRNAME(IXCSTR2) >> PATHOUT >> STRNAME(IXCSTR2) >> >> My Policy statements >> DATA TYPE(CFRM) REPORT(YES) >> DSN(SYS1.XCF.CFRM.CDS01) VOLSER(PLEX00) >> DEFINE POLICY NAME(WDSP2) REPLACE(YES) >> CF NAME(CFCC1) >> TYPE(SIMDEV) >> MFG(IBM) >> PLANT(EN) >> SEQUENCE(0000000CFCC1) >> PARTITION(0) >> CPCID(00) >> DUMPSPACE(2000) >> CF NAME(CFCC2) >> TYPE(SIMDEV) >> MFG(IBM) >> PLANT(EN) >> SEQUENCE(0000000CFCC2) >> PARTITION(0) >> CPCID(00) >> DUMPSPACE(2000) >> STRUCTURE NAME(IXCSTR1) >> SIZE(40000) >> INITSIZE(6000) >> PREFLIST(CFCC1,CFCC2) >> STRUCTURE NAME(IXCSTR2) >> SIZE(40000) >> INITSIZE(6000) >> PREFLIST(CFCC2,CFCC1) >> STRUCTURE NAME(ISGLOCK) >> SIZE(8448) >> INITSIZE(1000) >> PREFLIST(CFCC1,CFCC2) >> STRUCTURE NAME(LIST_01) >> SIZE(10000) >> INITSIZE(1000) >> PREFLIST(CFCC1,CFCC2) >> EXCLLIST(CACHE_01) >> STRUCTURE NAME(CACHE_01) >> SIZE(10000) >> REBUILDPERCENT(25) >> PREFLIST(CFCC2,CFCC1) >> EXCLLIST(LIST_01) >> STRUCTURE NAME(ISTGENERIC) >> SIZE(4096) >> REBUILDPERCENT(30) >> PREFLIST(CFCC1,CFCC2) >> STRUCTURE NAME(ISTMNPS) >> SIZE(4096) >> REBUILDPERCENT(30) >> PREFLIST(CFCC1,CFCC2) >> STRUCTURE NAME(SYSZWLM_WORKUNIT) >> SIZE(2000) >> INITSIZE(1000) >> PREFLIST(CFCC1,CFCC2) >> >> VM user directorie entries >> USER ZPLEX1 xxxxxx 2G 2G ABG >> INCLUDE WDSDFLT >> OPTION CFUSER TODENABLE >> IPL 190 PARM AUTOCR >> CONSOLE 01F 3270 >> SPECIAL 0400 MSGP CFCC1 >> SPECIAL 0500 MSGP CFCC2 >> >> USER ZPLEX2 xxxxxx 1G 1G ABG >> INCLUDE WDSDFLT >> MACH XA >> OPTION CFUSER TODENABLE >> IPL 190 PARM AUTOCR >> CONSOLE 01F 3270 >> SPECIAL 0400 MSGP CFCC1 >> SPECIAL 0500 MSGP CFCC2 >> >> USER CFCC1 CFCC1 512M 512M G >> XAUTOLOG CFCONSOL >> OPTION CFVM TODENABLE >> ACCOUNT 14 CFVMACNT >> MACH ESA >> CONSOLE 0009 3215 T CFCONSOL >> SPECIAL 0300 MSGP CFCC2 >> ******************************************** >> USER CFCC2 CFCC2 512M 512M G >> XAUTOLOG CFCONSOL >> OPTION CFVM TODENABLE >> ACCOUNT 14 CFVMACNT >> MACH ESA >> CONSOLE 0009 3215 T CFCONSOL >> SPECIAL 0300 MSGP CFCC1 >> >> ******************************************** >> * COUPLING FACILITY CONSOLE >> ******************************************** >> USER CFCONSOL CFCONSOL 2M 2M ABCDEFG >> INCLUDE WDSDFLT >> ACCOUNT 14 CFCGACNT >> MACH ESA >> CONSOLE 0009 3215 T >> MDISK 191 3390 0052 001 WDSVM1 MR ALL ALL >> >> ---------------- End of config members --------------------- >> >> ---------------------------------------------------------------------- >> For IBM-MAIN subscribe / signoff / archive access instructions, >> send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO >> Search the archives at http://bama.ua.edu/archives/ibm-main.html >> >> >> > > > -- Mark Jacobs Time Customer Service Tampa, FL ---- "...the very powerful and the very stupid have one thing in common, they don't alter their views to fit the facts, they alter the facts to fit their views." The Doctor, "The Face of Evil" ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html