Gadi, IBM is aware of this and they are fixing it with APAR OA27885. The SDSF was changed to work on JES2 or JES3 and in the process they left out the positional parameter which was used in default sort before V1.9.
HTH Natarajan >>> גדי בן אבי <[email protected]> 3/19/2009 1:16 AM >>> Hi, We cut over to z/Os 1.9 last week and we’re have some problems: 1. Performance on the Output screen is slow. 2. The order in which multiple SYSOUTS from the same job are displayed on the output screen is wrong. We have jobs that create many sysouts. All of the sysouts have the same parameters (CHARS, FORMDEF, PAGEDEF, CLASS). The job has FREE=CLOSE coded. Once the job finishes and we look at the sysouts in the output screen we see that instead of the order being 1,2,3… it is 1,10,11,2,3…, Or in other words, the sysouts are sorted textually instead of numerically. 3. The order of the jobs on the Status screen is different than it was previously. For example, if I submit a job and it is assigned job number 65000, I wait a while, submit another job and it is assigned job number 100, then the first job (number 65000) will be displays below the second job (number 100). I would like the jobs to be displayed in the order that they were submitted. Our previous operating system was z/OS 1.7, where we had none of the problems. Has anyone seen these problems? Do you know of a fix? Yes, I’ve opened problems with IBM. TIA Gadi ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html NOTICE OF CONFIDENTIALITY The information contained in this communication, including but not limited to any accompanying document(s) and/or attachment(s), is privileged and confidential and is intended solely for the above-named individual(s). If you are not the intended recipient, please be advised that any distribution, copying, disclosure, and/or use of the information contained herein is strictly prohibited. If you received this communication in error, please destroy all copies of the communication, whether in electronic or hard copy format, and immediately contact the Security Office at EDFUND at (916) 526-7539 or [email protected]. Thank you. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html