Jim, we just turned a 706 into a 707. IBM's stuff works great. No
issues. 
We also turned a 703 into a 603, no issues.

Are your HMC IMAGE profiles defined with reserved engines? That's a
requirement. 

After they get done just CF CPU(xx),ONLINE.

As to the ISVs, we notified them. Some products care about the
MSUs/MIPS, some care about model numbers, some only care about serial
numbers.

Some vendors thanked us and updated their records, some sent us new
product keys. 

Alan  



-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Horne, Jim - James S
Sent: Tuesday, May 12, 2009 12:09 
To: [email protected]
Subject: Adding CPU engines without IPL

Hi all,

We are planning to upgrade one of our 2094s dynamically from a 712 to a
714.  IBM assures us that their stuff will work.  Since we have the two
engines in reserve our understanding is that we can simply configure
them online without an IPL or Activate.  My question is in two parts.
Has anyone done this and were there any issues with third party
products?

Thanks,

Jim Horne
Systems Programmer
Large Systems Engineering & Messaging NC4IT