On Wed, 24 Jun 2009 08:25:21 -0500, Arthur Gutowski <[email protected]> wrote:
>I don't know about *your* automation product, but ours doesn't like "F >OMVS,SHUTDOWN" very much. AF/Oper has it's hooks into OMVS, and if you >kill OMVS before AF/Oper recedes on its own, things tend to get hung out to >dry, and we have very unhappy Operators (lots of extra keystrokes). We run that same product and our automation admins used to have a script that tried to do something with this. If they had just checked with the vendor or done a search (which I ended up doing for them), they would have found there is a documented process for terminating the links between systems that use TCPIP, thus removing the PID / use of z/OS Unix and allowing AFOPER to shut down OMVS without killing itself in the process. If you search ibm.com for "AFOPER OMVS SHUTDOWN" you will get this hit: http://www-01.ibm.com/support/docview.wss?uid=swg21196779 Mark -- Mark Zelden Sr. Software and Systems Architect - z/OS Team Lead Zurich North America / Farmers Insurance Group - ZFUS G-ITO mailto:[email protected] z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/ Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html