On Wed, 24 Jun 2009 08:25:21 -0500, Arthur Gutowski <[email protected]> wrote:

>I don't know about *your* automation product, but ours doesn't like "F
>OMVS,SHUTDOWN" very much.  AF/Oper has it's hooks into OMVS, and if you
>kill OMVS before AF/Oper recedes on its own, things tend to get hung out to
>dry, and we have very unhappy Operators (lots of extra keystrokes).

We run that same product and our automation admins used to have a 
script that tried to do something with this.  If they had just checked with
the vendor or done a search (which I ended up doing for them), they
would have found there is a documented process for terminating the
links between systems that use TCPIP, thus removing the PID / use
of z/OS Unix and allowing AFOPER to shut down OMVS without killing
itself in the process.

If you search ibm.com for "AFOPER OMVS SHUTDOWN" you will get
this hit:

http://www-01.ibm.com/support/docview.wss?uid=swg21196779

Mark
--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group - ZFUS G-ITO
mailto:[email protected]
z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html