If you are using DFDSS to clone, You would have to code BYPASSACS(**) NSC NMC 
to by pass SMS to assign null storage class and management class. .

Natarajan

>>> "Klein, Kenneth" <[email protected]> 6/24/2009 6:44 AM >>>
I think Jack is on to something here. I've been here 6 weeks and I am
NOT an sms guru. Could very well be the acs rules. My new peers are
telling me that these cloner jobs have recently (weeks ago) run fine but
only the sys1.* datasets are getting copied. All the ones like these
fail:

 
 AOP.SAOPEXEC
 CBC.SCCNJCL
 CEE.SCEEMSGP
 GLD.SGLDHDRC
 IOA.SIOAIBIN
 ISF.SISFJCL
 ACIF.SAPKMOD1
 AOP.SAOPMENU
 APK.SYS1.IBM.PARMLIB.V2
 ASM.SASMMAC1
 CBC.SCCNCMP
 CDS.SCDSSAMP
 CEE.SAFHFORT
 CIM.SCIMXML
 CMX.SCMXDBRM
 CSF.SCSFCLI0
 EOX.SEPHBOK1
 EOY.SEOXFONT
 EPH.SEPHCLIB
 EPH.SEPHSAMP D
 EUV.SEUVACF
 EUVF.SEUVFEXC
 FFST.V120ESA.SEPWBENU
 GDDM.SADMCDA
 GIM.SGIMCLS0
 GLD.SGLDEXEC
 GSK.SGSKSAMP
 HCM.SEEQINST
 ICQ.ICQABTXT
 IGY.SIGYCLST
 IMW.SIMWSDCK
 IOA.SIOAJAVA
 IOE.SIOEEXEC
 ISF.SISFEXEC
 ISP.SISPALIB
 JAVA.SAJVSMP1
 OMVS.JAVA31V5
 SCRIPT.R40.DCFASM
 SDF2.V1R4M0.SDGICMD
 TCPIP.SEZACMAC
 VSAPL.DZJDMY1

I'm hoping not to have rename all these files with &sysname or something
just to get them cataloged. I don't want to catalog them at all... but
then how will they be found when I IPL off the new res pack. I seem to
remember doing some cataloging with volser(******) or was that in the
dddef...

Any help greatly appreciated. Is there any doc on z/os maintenance
cloning best practices?


Ken Klein
Sr. Systems Programmer
Kentucky Farm Bureau Insurance - Louisville
[email protected] 
502-495-5000 x7011

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of John Kelly
Sent: Wednesday, June 24, 2009 8:16 AM
To: [email protected] 
Subject: Re: Veteran sysprog asks dumb question

Sounds like your bypass storage class (STORCLAS(SCNONSMS)) isn't taking
effect (SC=SCDFLT MC=STANDARD DC=), ie it seems like your omvs dsn are
going sms and that has to be catalogued.
SC=SCDFLT MC=STANDARD DC=

Jack Kelly
202-502-2390 (Office)

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send
email to [email protected] with the message: GET IBM-MAIN INFO Search
the archives at http://bama.ua.edu/archives/ibm-main.html 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

NOTICE OF CONFIDENTIALITY 

The information contained in this communication, including but not limited to 
any accompanying document(s) and/or attachment(s), is privileged and 
confidential and is intended solely for the above-named individual(s). If you 
are not the intended recipient, please be advised that any distribution, 
copying, disclosure, and/or use of the information contained herein is strictly 
prohibited. If you received this communication in error, please destroy all 
copies of the communication, whether in electronic or hard copy format, and 
immediately contact the Security Office at EDFUND at (916) 526-7539 or 
[email protected]. Thank you.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to