Ain't it the truth. Charles
-----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Miklos Szigetvari Sent: Thursday, October 04, 2012 10:46 AM To: [email protected] Subject: Message puzzle Hi The following simple message puzzle occurred: Try to XMIT a dataset from the linklist in TSO: Step 1 Got IEB1130E A TERMINATING MESSAGE FROM PDSE PROCESSING APPEARS ABOVE -- DIAGNOSTIC INFORMATION IS X'2822009F' Step 2 In LookAt unable to find IEB1130E, as only IEB1130I documented Step 3 Find in the Messages And Codes bookshelf the IEB1130E , refers to the DFDfp Diagnosis guide Step 4 In Diag Guide Convert the last two bytes (X'nnnn') of the reason code from hexadecimal to a decimal value and refer to that IGW01nnns message Step 5 Hurra , now I have it IGW01159T : Unable to obtain exclusive control of the input dataset. If it is so complicated, no wonder if "Another Light goes out" ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN