Ain't it the truth.

Charles

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Miklos Szigetvari
Sent: Thursday, October 04, 2012 10:46 AM
To: [email protected]
Subject: Message puzzle

     Hi

The following simple message puzzle occurred:

Try to XMIT a dataset from the linklist in TSO:
Step 1
Got
IEB1130E A TERMINATING MESSAGE FROM PDSE PROCESSING APPEARS ABOVE --
DIAGNOSTIC INFORMATION IS X'2822009F'

Step 2
In LookAt unable to find IEB1130E, as only IEB1130I documented

Step 3
Find in the Messages And Codes bookshelf the IEB1130E , refers to the DFDfp
Diagnosis guide

Step 4
In Diag Guide
Convert the last two bytes (X'nnnn') of the reason code
  from hexadecimal to a decimal value and refer to that IGW01nnns message

Step 5
Hurra , now I have it IGW01159T :
Unable to obtain exclusive control of the input dataset.


If it is so complicated, no wonder if "Another Light goes out"

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to