After issuing: SETSYS COMMONQUEUE(RECALL(CONNECT(test1)))

We get the following:
ARC1501I CONNECTION TO STRUCTURE SYSARC_TEST1_RCL WAS 664
ARC1501I (CONT.) UNSUCCESSFUL, RC=0C, REASON=02010C08                <==  X'0C' 
    The specified structure is temporarily unavailable.
IXL013I IXLCONN REQUEST FOR STRUCTURE SYSARC_TEST1_RCL FAILED. 662
JOBNAME: SYSHSM ASID: 0054 CONNECTOR NAME: HOSTCONNECTION5
IXLCONN RETURN CODE: 0000000C,  REASON CODE: 02010C08
NO SUITABLE COUPLING FACILITY IN PREFERENCE LIST
        CONADIAG0:   00000002
        CONADIAG1:   00000008
        CONADIAG2:   00000C08
IXL015I STRUCTURE ALLOCATION INFORMATION FOR 663
STRUCTURE SYSARC_TEST1_RCL, CONNECTOR NAME HOSTCONNECTION5,
CONNECTIVITY=DEFAULT
 CFNAME     ALLOCATION STATUS/FAILURE REASON
 --------   ----------------------------------------
 SYS3       NO CONNECTIVITY 8800F800
 SYS5       NO CONNECTIVITY 8800F800

Our sys1.parmlib has PLEXCFG=MULTISYSTEM,

We are at zos 1.13 with 4 LPARs on a single CEC.
One of our test LPARs has no tape connectivity so I thought I would eliminate 
the occasional grousing about tape recalls by setting up CRQ between the 2 
LPARs in the TEST Sysplex.

Question - Do we need an external coupling facility to do this?

I would have thought within a single CEC there would be internal connectivity.

TIA,
Dave O'Brien

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to